FANUC Power Mate i-MODEL H CONNECTION MANUAL (HARDWARE)

9. CONNECTION TO SERVO OR SPINDLE
B63173EN/03
332
1) Notes on mounting
(1)Use the unit inside a hermetically sealed cabinet.
(2)Mount the unit on a vertical face. Leave a space of 100 mm or
greater both above and below the unit. Do not place a device that
generates large amounts of heat below the unit.
(3)When using basic and additional units, mount them as shown in the
figure below, so that the flat cable connecting the units does not
block the vent hole of the basic unit.
The maximum length of the flat cable is 100 mm.
Vent hole
Flat cable
Basic unit Additional unit
2) If mounting with screws
Basic unit Additional unit
Mounting hole drilling diagram
When using both basic and additional units, the spacing between the
mounting holes must be 70 to 80 mm, as shown in the figure above.
9.2.10
Mounting