FANUC Power Mate i-MODEL H CONNECTION MANUAL (HARDWARE)

9. CONNECTION TO SERVO OR SPINDLE
B63173EN/03
338
CAUTION
The +5V terminal is used for optical link transmission via an
optical I/O link adapter. When using this cable or other
metallic cables, leave the +5V terminal open. If +5V is
supplied to this terminal when a metallic cable is used, +5
V for the Power Mate and that for the spindle module are
shortcircuited, then the unit is damaged.
NOTE
1 Recommended cable specification:
A66L00010284#10P (#28AWG x 10 pairs)
2 When this cable is routed near other cables, such as power
cables, connect the shield line to the grounding plate. This
connection is not, however, necessary when the Power
Mate and spindle amplifier module are mounted in close
proximity.
3 This cable can be used to connect the Power Mate and
spindle amplifier module electrically, when the Power Mate
and spindle amplifier module are mounted in the same
power magnetics cabinet or in power magnetics cabinets
which have been connected by welding or other means.
When mounted in separate power magnetics cabinets, the
Power Mate and spindle amplifier module must be
connected by an optical cable, via an optical I/O link
adapter.
4 Leave ES1, ES2, SVC1, and SVC2 unconnected; they are
used for the analog spindle.
5 Do not make any connection other than the above.

Leave a Reply