FANUC Power Mate i-MODEL H CONNECTION MANUAL (HARDWARE)

B63173EN/03
9. CONNECTION TO SERVO OR SPINDLE
357
Supply power to the analog servo interface unit from an external 24VDC
power supply.
CP11L
+24V
2
1
0V
3
GND1
+24V (1)
0V (2)
Analog servo interface unit (basic unit) External power supply
External power supply
24VDC regulated power supply
24 VDC "10% (including an
instantaneous value and ripple)
GND1 is the signal ground of the analog servo interface unit.
Connect GND1 to the grounding plate of the cabinet with a
Faston terminal (A02B0166K330).
Cable
AMP Japan, Ltd.
11782883 (housing)
11752185 (contact)
Select an appropriate cable
for the terminals of the
external power supply.
Recommended cable specification: A02B0124K830 (5 m)
An M3 crimp terminal is provided at the cable end on the external power supply side.
The 24VDC signal input to CP11L can be taken out from CP11M for the
purpose of branching. CP11M connection is the same as for CP11L.
Power supply: 24 VDC "10% (including an instantaneous value and
ripple)
One basic unit One basic unit + one
expansion unit
Type F 0.7 A 1.0 A
Type M 1.2 A (Note) 2.0 A (Note)
NOTE
For type M, 0.25 A of the 24V power for analog servo
amplifiers is included per axis.
9.5.6
Power Supply and Heat
Loss
9.5.6.1
Connection of the power
supply
9.5.6.2
Power supply capacity