FANUC Power Mate i-MODEL H CONNECTION MANUAL (HARDWARE)

10. CONNECTION TO PERIPHERALS
B63173EN/03
410
2) Details of cables J177 and J178
JD13 in setup/display device
(PCREV20MDT)
1 TXD 11 0V
2 *TXD 12 0V
3 RXD 13 (SI1)
4 *RXD 14 (*SI1)
5 (ITPGA) 15 (SI2)
6 (*ITPGA) 16 (*SI2)
7 (ITPGB) 17 (SI3)
8 (*ITPGB) 18 (*SI3)
9 (SIO) 19
10 20 (*SIO)
J177 J178
JD13
TXD
*TXD
RXD
*RXD
0V
0V
0V
0V
1
2
3
4
11
12
J177
J178
RXD
*RXD
TXD
*TXD
Cabinet
Connector panel
Cable connection
Setup/display device
Shield
Shield
Connection
panel
Cabinet
Connector
panel
Recommended cable: A66L00010284#10P (#28AWG 10 pairs, common shield) <Hitachi Cable, Ltd., Oki Electric Cable Co., Ltd.>
Recommended connector on the cable side (JD13): PCRE20FS or PCRE20FA, housing: PCRV20LA <Honda Tsushin>
NOTE
1 Make no connection to a pin with no name indicated or its name parenthesized in connector
JD13.
2 The shield of cable J177 must be grounded when connected to the cabinet.
3 Do not change the combination of the wires of twisted pairs.