D. OPTICAL FIBER CABLE
B63173EN/03
APPENDIX
480
D
OPTICAL FIBER CABLE
This section describes the specifications and notes of the optical fiber
cables for the following interfaces.
(1) Serial spindle interface (for internal lines)
(2) I/O Link interface (for exchange lines)
(3) Highspeed serial bus (HSSB) interface (for exchange lines)
(4) Serial servo bus (FSSB) interface (for internal or exchange lines)
(1)Supported optical cables
(a) Internal cord type cable: A66L60010023#LjRjjj
Cable length: 0.15 to 10 m
Code diameter: 2.2 mm × 2 cords
Tensile strength:
Fiber cord 7 kg per cord
Between optical fiber cord and optical connector 2 kg
Minimum bending radius of fiber cord: 25 mm
Operating temperature: 20 to 70°C
7
6.7 14 max. 100 typ.
21
Unit: mm
Two cords are bound together.
Fiber code
Fig. D (a) External dimensions of internal cord type cable
(b)External type cable: A66L60010026#LjRjjj
A66L60010029#LjRjjj
Cable length: 1 to 200 m
Fiber cord diameter: 2.2 mm × 2 cords
Diameter of cable with reinforced cover: 7.6 mm
Tensile strength: Cable with reinforced cover: 75 kg
Optical fiber cord: 7 kg per cord
Between fiber cord and optical connector: 2 kg
Minimum bending radius of optical fiber cord: 25 mm
Minimum bending radius of cable with reinforced cover: 50 mm
Bending resistance (cable with reinforced cover):
10 million bending cycles at room temperature
(when the bending radius is 100 mm)