40
D If the FANUC I/O Link master uses 200VAC power
200VAC
Power Mate i
ON OFF COM
Main
breaker
Electromagnetic
contacts
AC line
filter
Servo
converter
Servo
inverter
3phase
200 VAC
for motive
power
Singlephase
200 VAC for
control
External
24VDC stabi-
lized power
source
24VDC
input
24VDC
input
24VDC
input
24VDC
input
200VA C
input
ON/OFF
circuit
CRT/MDI, etc.
FANUC I/O Link
slave (such as
an I/O card)
Separate detector
I/F unit
FSSB I/O module
FANUC I/O Link
master (such as
a CNC)
Fig. 5.2 (c)
NOTE
1 In Fig. 5.2 (c), the 24VDC power source must have a
startup time not exceeding 500 ms.
2 In Figs. 5.2 (a) to 5.2 (c), the FANUC I/O Link slave (such as
an I/O card) is a slave of the Power Mate i.
3 In Figs. 5.2 (b) and 5.2 (c), the FANUC I/O Link master (such
as a CNC) acts as the master for the Power Mate i.
The power to separate detectors (scales) can be supplied from the
separate detector interface unit, provided that the current (voltage) is
0.35 A (5 V) or less per scale. Note that the separate detector (scale)
to which the power is to be supplied from the separate detector
interface unit must be such that the A/Bphase signal is stabilized
within 500 ms of the power being turned on.