Fanuc Series 15i/150i-MA (Programming) Operators Manual

C.RANGE OF COMMAND VALUE APPENDIX B-63324EN/03
- 766 -
NOTE
*1 The feed rate range shown above are limitations
depending on CNC interpolation capacity. When
regarded as a whole system, limitations, depending
on the servo system, must also be considered.
*2 Incremental feed amount can be specified by setting
amount (parameter setting.)
*3 The values are applied when the offset extension
function is used.
When input is switched between inch input and metric
input, note the following. The maximum
compensation value that can be set in inch input
mode is (maximum compensation value) x 1/25.4.
If a compensation value beyond this limit is input in
inch input mode, the value cannot be converted
correctly to a metric value in metric input mode.
*4 The unit of backlash compensation is detection unit.
*5 Will depend on the unit system of the axis on address
X.