Fanuc Series 15i/150i-MA (Programming) Operators Manual

F.ALARM LIST APPENDIX B-63324EN/03
- 794 -
Number Message Contents
PS0540 ADDRESS E OVERFLOW
(OVERRIDE)
The speed obtained by applying override to the E
instruction is too fast.
PS0541 S-CODE ZERO "0" has been instructed as the S code.
PS0542 FEED ZERO (E-CODE) "0" has been instructed as the feedrate (E code).
PS0543 ILLEGAL GEAR SETTING The gear ratio between the spindle and position coder, or
the set position coder number of pulses is illegal in the
spindle position function and the rigid tapping function.
PS0548 ILLGAL AXIS MODE The spindle positioning axis/Cs contour control axis was
specified during switching of the controlled axis mode.
PS0551 DUPLICATE SPOS AXIS COMMAND Two or more axes were specified on a single spindle
positioning axis. (e.g. positioning by an M code or
positioning by an axis address)
PS0552 SPOS AXIS - OTHER AXIS SAME
TIME
The spindle positioning axis and another axis are specified
in the same block.
PS0553 SPOS AXIS ILLEGAL SEQUENCE
NUMBER
Operation sequence pattern setting parameter No. 5895 for
spindle positioning is out of range.
PS0555 SPOS AXIS DUPLICATE AXIS
COMMAND
The spindle positioning instruction has been issued to a
spindle that is currently moving or which the instructed
spindle positioning sequence has not completed.
PS0561 ILLEGAL INDEXING ANGLE The specified angle of rotation is not an integer multiple of
the minimum indexing angle.
PS0562 INDEX TABLE AXIS COMMAND CAN
NOT START
The specified index table indexing sequence is illegal.
PS0563 EXCESS ERROR OF INDEXING
ANGLE
The specified index table indexing angle is illegal.
PS0564 INDEX TABLE AXIS - OTHER AXIS
SAME TIME
The index table indexing axis and another axis have been
specified in the same block.
PS0566 INDEX TABLE AXIS DUPLICATE
AXIS MODE
A move instruction has been issued to an axis that is not an
index table indexing axis.
PS0567 INDEX TABLE AXIS DUPLICATE
AXIS COMMAND
Index table indexing was specified during axis movement or
on an axis for which the index table indexing sequence was
not completed.
PS0571 CS AXIS DUPLICATE AXIS MODE The Cs contour control axis has been specified on an axis
that is not in the Cs contour control mode.
PS0572 CS AXIS DUPLICATE AXIS
COMMAND
A currently moving axis has been specified as the Cs
contour control axis.
PS0580 ENCODE ALARM (PSWD&KEY) When an attempt was made to read a program, the
specified password did not match the password on the tape
and the password on tape was not equal to 0.
When an attempt was made to punch an encrypted tape,
the password was not in the range 1 to 99999999.
The password parameter is No. 2210.
PS0581 ENCODE ALARM (PARAMETER) When an attempt was made to punch an encrypted tape,
the punch code parameter was set to EIA. Set EIA
parameter No. 0000#4 to "0".
An incorrect instruction was specified for program
encryption or protection. This alarm is also generated when
the protected range is edited or deleted in a program-
locked state.
The protected range is defined from the program No. preset
by parameter No. 2212 up to the program No. preset to
parameter No. 2213. When both parameters are set to "0",
the protected range becomes O9000 to O9999.
PS0590 TH ERROR A TH error was detected during reading from an input
device.
The read code that caused the TH error and how many
statements it is from the block can be verified in the
diagnostics screen.
PS0591 TV ERROR An error was detected during the single-block TV error.
The TV check can be suppressed by setting TVC
parameter No. 0000#0 to "0".