Fanuc Series 15i/150i-MA (Programming) Operators Manual

B-63324EN/03 APPENDIX F.ALARM LIST
- 799 -
F.2 BG ALARM (ALARMS RELATED TO BACKGROUND EDIT)
Number Message Contents
BG0590 TH ERROR A TH error was detected during reading from an input
device.
The read code that caused the TH error and how many
statements it is from the block can be verified in the
diagnostics screen.
BG0591 TV ERROR An error was detected during the single-block TV error.
The TV check can be suppressed by setting TVC
parameter No. 0000#0 to "0".
BG0592 END OF RECORD The EOR (End of Record) code is specified in the middle of
a block.
This alarm is also generated when the percentage at the
end of the NC program is read.
BG0805 ILLEGAL COMMAND An attempt was made to specify an illegal command during
I/O processing on an I/O device.
BG0806 DEVICE TYPE MISS MATCH An operation not possible on the I/O device that is currently
selected in the setting was specified.
This alarm is also generated when file rewind is instructed
even though the I/O device is not a FANUC Cassette.
BG0807 PARAMETER SETTING ERROR An I/O interface option that has not yet been added on was
specified.
The external I/O device and baud rate, stop bit and protocol
selection settings are erroneous.
BG0808 DEVICE DOUBLE OPENED An attempt was made to open a device that is being
accessed.
BG0820 DR OFF(1) The data set ready input signal DR of the I/O device
connected to reader/punch interface 1 turned OFF.
BG0822 OVERRUN ERROR(1) The next character was received from the I/O device
connected to reader/punch interface 1 before it could read
a previously received character.
BG0823 FRAMING ERROR(1) The stop bit of the character received from the I/O device
connected to reader/punch interface 1 was not detected.
BG0824 BUFFER OVERFLOW(1) The NC received more than 10 characters of data from the
I/O device connected to reader/punch interface 1 even
though the NC sent a stop code (DC3) during data
reception.
BG0830 DR OFF(2) The data set ready input signal DR of the I/O device
connected to reader/punch interface 2 turned OFF.
BG0832 OVERRUN ERROR(2) The next character was received from the I/O device
connected to reader/punch interface 2 before it could read
a previously received character.
BG0833 FRAMING ERROR(2) The stop bit of the character received from the I/O device
connected to reader/punch interface 2 was not detected.
BG0834 BUFFER OVERFLOW(2) The NC received more than 10 characters of data from the
I/O device connected to reader/punch interface 1 even
though the NC sent a stop code (DC3) during data
reception.
BG0840 DR OFF(3) The data set ready input signal DR of the I/O device
connected to reader/punch interface 3 turned OFF.
BG0842 OVERRUN ERROR(3) The next character was received from the I/O device
connected to reader/punch interface 3 before it could read
a previously received character.
BG0843 FRAMING ERROR(3) The stop bit of the character received from the I/O device
connected to reader/punch interface 3 was not detected.
BG0844 BUFFER OVERFLOW(3) The NC received more than 10 characters of data from the
I/O device connected to reader/punch interface 3 even
though the NC sent a stop code (DC3) during data
reception.
BG0850 DR OFF(4) The data set ready input signal DR of the I/O device
connected to reader/punch interface 4 turned OFF.