Fanuc Series 15i/150i-MA (Programming) Operators Manual

B-63324EN/03 APPENDIX F.ALARM LIST
- 805 -
Number Message Contents
SV0060 FSSB:OPEN READY TIME OUT The FSSB was not in a ready to open state during
initialization.
A probable cause is an axis card malfunction.
SV0061 FSSB:ERROR MODE The FSSB entered the error mode.
Probable causes are an axis card or amplifier malfunction.
SV0062 FSSB:NUMBER OF AMP. IS
INSUFFICIENT
The number of amplifiers identified by the FSSB is less
than the number of controlled axes.
The set number of axes or the amplifier connection is
erroneous.
SV0063 FSSB:CONFIGURATION ERROR The FSSB configuration error occurred. Or, there is a
difference in the type of connected amplifier and FSSB
setting.
SV0064 FSSB:AXIS SETTING NOT
COMPLETE
Setting of axes was not completed in the automatic setting
mode.
SV0065 FSSB:OPEN TIME OUT FSSB did not open even though FSSB initialization was not
completed. Or, the connection between the CNC and
amplifier is incorrect.
SV0066 FSSB:ID DATA NOT READ Amplifier information cannot be read as FSSB is not
assigned. Or, the connection between the CNC and
amplifier is incorrect.
SV0067 FSSB:CONFIGURATION
ERROR(SOFT)
The FSSB configuration error occurred. (Detected in
software). Or, there is a difference in the type of connected
amplifier and FSSB setting.
SV0070 FSSB DISCONNECT FSSB communications was broken; the FSSB
communications cable was disconnected, or broken; the
amplifier power supply turned OFF; or, the low voltage
alarm occurred on the amplifier.
SV0071 ILLEGAL AMP. INTERFACE The axes of a 2-axis amplifier were assigned to a fast-type
interface; or, the axis setting was incorrect.
SV0072 SEND CNC DATA FAILED An FSSB communications error prevented correct data
from being sent or received by the slave.
SV0073 SEND SLAVE DATA FAILED An FSSB communications error prevented correct data
from being sent or received by the servo software.
SV0074 READ ID DATA FAILED Failed to read amplifier ID information during power ON.
SV0075 MOTOR/AMP. COMBINATION The maximum current of the motor is different from the
maximum current of the amplifier; the connection between
the axis and amplifier is incorrect; or, the parameter setting
is incorrect.
SV0076 ILLEGAL SETTING OF AXIS The setting is incorrect even though functions requiring
hardware for 2 axes are built into one axis.
SV0100 S-COMP. VALUE OVERFLOW The value set for straightness compensation has exceeded
maximum value 32,767.
SV0101 DATA ERROR(ABS PCDR) A correct machine position cannot be obtained as the
absolute pulse coder has malfunctioned or the machine
moved too far during power ON.
SV0109 EXCESS ERROR (G31) The position deviation during execution of torque limit
switch operation exceeds the limit setting of parameter No.
1843.
SV0119 ABNORMAL TORQUE(1ST SPDL) An abnormal load was detected at the No. 1 spindle motor.
This alarm is canceled by resetting the control.
SV0120 ABNORMAL TORQUE(2ND SPDL) An abnormal load was detected at the No. 2 spindle motor.
This alarm is canceled by resetting the control.
SV0125 EXCESS VELOCITY IN TORQUE In torque control, the specified permissible speed was
exceeded.
SV0126 EXCESS ERROR IN TORQUE In torque control, the maximum accumulated speed
specified in parameters was exceeded.
SV0127 ABNORMAL TORQUE(3RD SPDL) An abnormal load was detected at the No. 3 spindle motor.
This alarm is canceled by resetting the control.
SV0128 ABNORMAL TORQUE(4TH SPDL) An abnormal load was detected at the No. 24 spindle
motor. This alarm is canceled by resetting the control.