Assign the signal address and the bit image address of the key switch and
LED signal as follows.
(It is available from vers. 2.3 of FAPT LADDER on the P–G Mate)
KEY IN ONE OF THE FOLLOWING NO.S WHICH YOU WANT TO SET PARA, S.
NO. ITEMS CURRENT PARAMETERS
01 (UNUSED) ;
02 COUNTER DATA TYPE ; BINARY
03 OPERATOR PANEL ; YES
KEY/LED ADDRESS ; X0000/Y0000
KEY/LED BIT IMAGE ADRS. ; R0900/R0910
04 PMC TYPE ; PMC–RB
05 (UNUSED) ;
06 (UNUSED) ;
07 LADDER EXEC. ; 100%
08 (UNUSED) ;
09 IGNORE DIVIDED CODE ; NO
10 (UNUSED) ;
00 NOTHING TO SET ;
NO.=
1) Select menu No. “3” on Parameter Screen.
Then, following message appears.
EXAMPLE 0:NO, 1:YES
OP.PANEL=_
2) Select “1” on example menu.
Then , following message appears.
SET KEY/LED ADDRESS (KEY ADRS. , LED ADRS.)
ADDR=_
3) Set PMC ADDRESS (X and Y) for KEY and LED signals.
For example, if you want to set X0 for key switches and Y0 for LEDs,
type “X0, Y0” and [NL].
Then, following message appears.
SET KEY/LED BIT IMAGE ADDRESS (KEY ADRS. , LED ADRS.)
ADDR=_
4) Set PMC ADDRESS for BIT IMAGE.
For example R900 and R910 if you want. Set “R900, R910” [NL].
Then, return to Parameter Screen and following message appears.
:::
03 OPERATOR PANEL ; YES
KEY/LED ADDRESS ; X0000/Y0000
KEY/LED BIT IMAGE ADRS. ; R0900/R0910
:::