FANUC Series 16/18/160/180-Model C Connection Manual (Hardware)

B–62753EN/01
6. CONNECTION OF I/O UNITS TO
MACHINE INTERFACE
129
Notes
1. As a result of above operation, Table 6.7(a), (b), (c) are assigned for
the PMC address as follows.
Xn X0000 Rk / RI R0900/ R0910
Xn+1 X0001 Rk+1 / RI+1 R0901/ R0911
Xn+2 X0002 Rk+2 / RI+2 R0902/ R0912
Rk+3 / RI+3 R0903/ R0913
Ym Y0000 Rk+4 / RI+4 R0904/ R0914
Rk+5 / RI+5 R0905/ R0915
Rk+6 / RI+6 R0906/ R0916
Rk+7 / RI+7 R0907/ R0917
2. In case of I/O card
PMC address in the I/O Card is fixed. Therefore, set the fixed
address for the used signal at operation 3) in above operation.
ex) If X1000, X1001, X1002, Y1000 are used for the key switches
and LEDs, type as follows.
SET KEY/LED ADDRESS (KEY ADRS. , LED ADRS.)
ADDR= X1000, Y1000 [NL]