FANUC Series 16/18/160/180-Model C Connection Manual (Hardware)

B–62753EN/01
6. CONNECTION OF I/O UNITS TO
MACHINE INTERFACE
155
The bits with a signal name in the table are used for fixed address signals
which are directly referenced by the CNC. Other bits can be assigned to
arbitrary machine interface signals. When a fixed address signal is used,
the corresponding bit cannot be used for other interface signals.
Address Bit No.
76543210
Connector
pin
number
C71–B05
C71-A05 C71-B04 C71-A04 C71-B03 C71-A03 C71-B02 C71-A02
X1000
C71-B10
C71-A10 C71-B09 C71-A09 C71-B08 C71-A08 C71-B07 C71-A07
X1001
C71-B14
C71-A14 C71-B13 C71-A13 C71-B12 C71-A12 C71-B11 C71-A11
X1002
C71-B19
C71-A19 C71-B18 C71-A18 C71-B17 C71-A17 C71-B16 C71-A16
X1003
C70-B10
C70-A10 C70-B09 C70-A09 C70-B08 C70-A08 C70-B07 C70-A07
X1006
C70-B14
C70-A14 C70-B13 C70-A13 C70-B12 C70-A12 C70-B11 C70-A11
C70-B19
C70-A19 C70-B18 C70-A18 C70-B17 C70-A17 C70-B16 C70-A16
X1008
C70-B23 C70-A23 C70-B22 C70-A22 C70-B21 C70-A21 C70-B20 C70-A20
X1009
C70-B05
C70-A05 C70-B04 C70-A04 C70-B03 C70-A03 C70-B02 C70-A02
X1005
C71-B23
C71-A23 C71-B22 C71-A22 C71-B21 C71-A21 C71-B20 C71-A20
X1004
(T series)
(M series)
SKIP
SKIP
ZAE YAE XAE
–MIT2 +MIT2 –MIT1 +MIT1 ZAE XAE
*ESP
*DEC8 *DEC7 *DEC6 *DEC5 *DEC4 *DEC3 *DEC2 *DEC1
ESKIP
ESKIP
I/O
card
C or G
I/O
card
B or F
I/O
card
A or E
I/O
card
D or H
Continued on next page
X1007