B–62753EN/01
7. CONNECTION TO CNC PERIPHERALS
169
TXD1 RXD
2 0V
3
4 0V
11
12 TXD
13
14 0V
5 *RXD
6 0V
7
8
15
16 0V
17
18 *TXD
9
10 (+24V)
19 (+24V)
20
CNC
JA1
(PCR-EV20MDT)
( ): Signals not used.
CP2 or CP3
(AMP)
1 200A
2 200B
3 G
1 +24V
2 0V
3
CP5
(AMP)
14CRT/MDI unit
LCD/MDI unit
JN1
(PCR-EV20MDT)
1 200A
2 200B
3 G
1
2
3
+24V
0V
CP5
(AMP)
CN2
HIROSE
FI40A–20S(Connector)
FI–20–CV5(Case)
Cable wiring
1
2
1
2
RXD
0V
TXD
0V
3
4
3
4
0V 0V
5
6
5
6
*RXD
0V
*TXD
0V
18
16
18
16
*TXD
0V
*RXD
0V
12
14
12
14
TXD
0V
RXD
0V
Recommended cable material
A66L–0001–0371 Coaxial cable (Max. 50m)
1
2
0V
3
4 0V
11
12 RXD
13
14 0V
5 *TXD
6 0V
7
8
15
16 0V
17
18 *RXD
9
10
19
20
AMP
1–178128–3(Housing)
1–175218–5(Contact)
Only for 14”CRT
In case of LCD
AMP
2–178288–3(Housing)
1–175218–5(Contact)
Ground
Be sure to connect the
protective ground.
Grounding plate
14 CRT, LCD display
interface