FANUC Series 16/18/160/180-Model C Connection Manual (Hardware)

7. CONNECTION TO CNC PERIPHERALS
B–62753EN/01
178
1
FG SD RD RS CS DR SG CD
2 3 4 5 6 7 8 9 10 11 12 13
14 15 16 17 18 19 20 21 22 23 24 25
ER +24
1 RD
2 0V
3 DR
4 0V
11 SD
12 0V
13 ER
14 0V
5 CS
6 0V
7 CD
8 0V
15 RS
16 0V
17
18
9 19 +24V
CNC
JD5A, JD5B
(PCR-EV20MDT)
10 +24V 20
FG
200VAC (+10%, –15%)
50/60Hz"1Hz, 110VA (Without reel)
50/60Hz"1Hz, 130VA (With reel)
Portable
tape
reader
Cable side plug
WF7013 (MATSUSHITA
ELECTRIC WORKS CO., LTD.)
Plug receptacle
WF3012E (MATSUSHITA
ELECTRIC WORKS CO., LTD.)
Relaying connector signal layout
Input power supply
Relaying
cable
Relaying connector
Connector : DBM-25S
(JAPAN AVIATION ELECTRONIC
INDUSTRY., LTD.)
Lock metal : D20418-J2
(JAPAN AVIATION ELECTRONIC
INDUSTRY., LTD.)
Cable side connector
Connector : DBM-25P
(JAPAN AVIATION ELECTRONIC
INDUSTRY., LTD.)
Lock metal : DB–C2–J9
(JAPAN AVIATION ELECTRONIC
INDUSTRY., LTD.)
Accessory
for portable
tape reader
Notes
1. Prepare the relaying connector, the relaying cable and the
plug receptacle at the machine tool builder.
2. Prepare the power supply for PPR at the machine tool
builder.
3. Use the unified shielded cable for signal cable.
Recommended cable specification : A66L-0001-0041
4. When connecting the portable tape reader, set the
corresponding parameter to use reader puncher interface
(baud rate is 4800 baud).
7.2.3
Portable Tape Reader
Connection

Leave a Reply

Your email address will not be published. Required fields are marked *