FANUC Series 16/18/160/180-Model C Connection Manual (Hardware)

7. CONNECTION TO CNC PERIPHERALS
B–62753EN/01
180
CNC
200A 200B G
Cable wiring
SD
RD
RD
SD
ER
RS
DR
CS
DR RDY
CD
SG
(0V)
SG
FG
1 RD
2 0V
3 DR
4 0V
11 SD
12 0V
13 ER
14 0V
5 CS
6 0V
7 CD
8 0V
15 RS
16 0V
17
18
9 19 +24V
JD5A, JD5B
(PCR-EV20MDT)
10 +24V 20
1
RSG
23
CP2, CP3
200A 200B G
1 FG
2 SD
3 RD
4
5
6 DR
7 SG
8
9
10
11 RDY
12
13
14
15
16
17
18
19
20
21
22
23
24
25
M3 screw terminal
TApe reader
AMP
1-178128-3
Connector :
DB-25P
Lock metal
D110278
(JAPAN AVIATION
ELECTRONIC
INDUSTRY., LTD.)
DB-25S-T
(JAPAN AVIATION
ELECTRONIC
INDUSTRY., LTD.)
Control unit
FG
Tape reader
(3)
(2)
(6)
(11)
(7)
(1)
Use cable clamp
Notes
1. Note that the lines with the same signal names on the
control unit and the tape reader cannot be connected.
2. Use a unified shield cable for signal cable.
Recommended cable specification : A66L-0001-0041
7.2.5
Connection of Tape
Reader without Reels