FANUC Series 16/18/160/180-Model C Connection Manual (Hardware)

B–62753EN/01
7. CONNECTION TO CNC PERIPHERALS
181
CNC
Cable wiring
SD
RD
RD
SD
CS
RS
CS
DR
CD
ER
ER
SG
(0V)
SG
1 RD
2 0V
3 DR
4 0V
1111 SD
1212 0V
1313 ER
1414 0V
5 CS
6 0V
7 CD
8 0V
1515 RS
1616 0V
1717
1818
9 1919 +24V
JD5A, JD5B
(PCR-EV20MDT)
1010 +24V 2020
1
RSG
23
 
Tape reader
AMP JAPAN, LTD.
1-178128-3
MR–20LFH
CD8 (MR–20RM)
Control unit
FG
Tape reader
(9)
(8)
(19)
(5)
(17)
Use cable clamp.
1
RSG
23
CP41
RS
DR
(20)
(18)
BURNDY JAPAN, LTD.
SMS3PK–5
1
2
3
4
1111
1212
1313
1414
5 ER
6
7
8 RD
1515
1616
1717 SG
1818 DR
9 SD 1919 CS
10 2020 RS
CD8
Notes
1. Note that the lines with the same signal names on the
control unit and the tape reader cannot be connected.
2. Use a unified shield cable for signal cable.
Recommended cable specification : A66L-0001-0041
7.2.6
Connection of Tape
Reader with Reels