FANUC Series 16/18/160/180-Model C Connection Manual (Hardware)

3. INSTALLATION
B–62753EN/01
16
Heat exchanger
Air outlet
Outside Inside
Air outlet
Air inlet
Main body of
heat exchanger
Finger guard
(attached)
External cooling fan
(attached)
(1)
(1)
(3)
(4)
(1) Use M5 screws to mount the heat exchanger.
(2) Be careful with air flow when securing the external cooling fan.
(3) Prepare a mounting panel for external cooling fan and install the panel where it can be exchanged externally.
(4) Drill mounting holes for external cooling fan and air outlet on heat exchanger mounting panel.
Prepare
mounting
screws and
mounting panel
220
378
22020 20
480
390
70
50 10
10
23 15=345
15
Fig. 3.6.2(b) Mounting methods of heat exchanger for CRT/MDI