FANUC Series 16/18/160/180-Model C Connection Manual (Hardware)

3. INSTALLATION
B–62753EN/01
18
The heat pipe type heat exchanger is used for cooling the airtight cabinet
of small sized electronic devices. It is a compact, lightweight, and
heat–efficient unit. Because the fan is built–in, it is used simply by
installing it, performing the ”panel cut’ operation.
Installation format Installation type in board
Fan
specifications
Cooling ability (W/°C) 9 (50Hz when operating)
spec
ifi
ca
ti
ons
Voltage (V) 200VAC
Frequency (Hz) 50 60
Rating current (A) 0.28 0.24
Rating input (W) 28 26
Weight (kg) 4
Color Munsell signal N1.5
Order specifications
Heat exchanger A02B–0094–C901
Remarks
A filter is installed on the outside air inhalation side.
The installation board thickness is the standard 1.6 t.
When a fan motor and filter are necessary for maintenance, prepare
them separately.
Fan motor specifications
A90L–0001–0219#A
Filter specifications
A250–0689–X004
If the heat exchanger is installed near the CRT, screen distortion may
occur due to magnetic flux leakage from the fan motor.