FANUC Series 16/18/160/180-Model C Connection Manual (Hardware)

B–62753EN/01
3. INSTALLATION
27
The CNC cables that require shielding should be clamped by the method
shown below. This cable clamp treatment is for both cable support and
proper grounding of the shield. To insure stable CNC system operation,
follow this cable clamp method.
Partially peel out the sheath and expose the shield. Push and clamp by
the plate metal fittings for clamp at the part. The ground plate must be
made by the machine tool builder, and set as follows :
Cable
Metal fittings
for clamp
Ground plate
40 mm to 80 mm
Fig. 3.7.5(a) Cable clamp (1)
3.7.5
Cable Clamp and
Shield Processing