FANUC Series 16/18/160/180-Model C Connection Manual (Hardware)

B–62753EN/01
6. CONNECTION OF I/O UNITS TO
MACHINE INTERFACE
75
I/O Unit–A
AIF01A
I/O Unit–A
AIF01B
24VDC
24VDC
K2X
K1X
K1X
AIF01A AIF01B
24VDC 24VDC
K2X
K1X
AIF01A
AIF01B
JD1B
JD1A
JD2
CP32
JD3
JD2
PC32
24VDC 24VDC
K2X
Control unit
Terminator TX
⋅⋅⋅
Max.
16
group
JD1B
JD1A
JD2
CP32
JD1B
JD1A
JD2
CP32
JD3
JD2
PC32
JD3
JD2
PC32
JD1A
Notes
1. Number of I/O Units and connecting method are restricted
depending on the allocation of the I/O points.
See 6.2 “Connection of FANUC I/O Link” and 6.3.11
“Number of I/O points for the I/O Unit–A”.
2. Cable K1X can be an optical fiber cable by using the optical
I/O link adapter.
Refer to item 6.2.3.
6.3.4
Connection Diagram