FANUC Series 16/18/160/180-Model C Connection Manual (Hardware)

B–62753EN/01
6. CONNECTION OF I/O UNITS TO
MACHINE INTERFACE
87
Two inputs (input voltage: 0 to +10 V)
Input voltages are converted from analog to digital. The resulting five
bits of data are sent to the CNC through the FANUC I/O Link.
The analog signal input function can be used regardless of whether I/O
link allocation is 128/128 or 256/256.
Emergency stop and OT release signals are forwarded without change
to the power magnetics cabinet.
Power ON/OFF control signals are forwarded without change to an
input unit.
Analog signal inputs described in item “Analog signal inputs” can be
sent out without being changed.
This function may not be applicable depending on the type of CNC
connected. Be sure to check before using.
Analog signal inputs
Terminal for signal
forwarding
First manual pulse
generator