OPERATION
B–62754EN/01
3. MANUAL OPERATION
473
To enable manual per revolution feed, set bit 4 (JRV) of parameter No.
1402 to 1.
During manual per revolution feed, the tool is jogged at the following
feedrate:
Feed distance per rotation of the spindle (mm/rev) (specified with
parameter No. 1423) x JOG feedrate override x actual spindle speed
(rev/min).
Feedrate, time constant and method of automatic acceleration/
deceleration for manual rapid traverse are the same as G00 in programmed
command.
Changing the mode to the JOG feed mode while pressing a feed axis and
direction selection switch does not enable JOG feed. To enable JOG feed,
enter the JOG feed mode first, then press a feed axis and direction
selection switch.
If reference position return is not performed after power–on, pushing
RAPID TRAVERSE button does not actuate the rapid traverse but the
remains at the manual continuous feedrate. This function can be disabled
by setting parameter RPD (No.1401#01).
Explanations
D Manual per revolution
feed
Restrictions
D Acceleration/decelera–
tion for rapid traverse
D Change of modes
D Rapid traverse prior to
reference position return