Parameter 3402 (CLR) is used to select whether resetting the CNC places
it in the cleared state or in the reset state (0: reset state/1: cleared state).
The symbols in the tables below mean the following :
f:The status is not changed or the movement is continued.
×:The status is cancelled or the movement is interrupted.
Item When turning power on Cleared Reset
Setting
data
Offset value f f f
data
Data set by the
MDI setting opera-
tion
f f f
Parameter f f f
Various
data
Programs in
memory
f f f
Contents in the
buffer storage
× × f : MDI mode
× : Other mode
Display of se-
quence number
f f (Note 1) f (Note 1)
One shot G code × × ×
Modal G code Initial G codes.
(The G20 and G21 codes
return to the same state they
were in when the power was
last turned off.)
Initial G codes.
(G20/G21 are not
changed.)
f
F Zero Zero f
S, T, M × f f
K (Number of re-
peats)
× × ×
Work coordinate value Zero f f