FANUC Series 16/18/160/180-Model C for Lathe Operator Manual

APPENDIX
G. ALARM LIST
B–62754EN/01
760
Number ContentsMessage
115 ILLEGAL VARIABLE NUMBER A value not defined as a variable number is designated in the custom
macro or in high–speed cycle cutting.
The header contents are improper in a high speed cycle cutting. This
alarm is given in the following cases:
1. The header corresponding to the specified machining cycle num-
ber called is not found.
2. The cycle connection data value is out of the allowable range
(0 – 999).
3. The number of data in the header is out of the allowable range
(0 – 32767).
4. The start data variable number of executable format data is out of
the allowable range (#20000 – #85535).
5. The storing data variable number of executable format data is out
of the allowable range (#85535).
6. The storing start data variable number of executable format data is
overlapped with the variable number used in the header.
Modify the program.
116 WRITE PROTECTED VARIABLE The left side of substitution statement is a variable whose substitution
is inhibited. Modify the program.
118 PARENTHESIS NESTING ERROR The nesting of bracket exceeds the upper limit (quintuple).
Modify the program.
119 ILLEGAL ARGUMENT The SQRT argument is negative, BCD argument is negative, or other
values than 0 to 9 are present on each line of BIN argument.
Modify the program.
122 QUADRUPLE MACRO
MODAL–CALL
The macro modal call is specified in double.
Modify the program.
123 CAN NOT USE MACRO COMMAND
IN DNC
Macro control command is used during DNC operation.
Modify the program.
124 MISSING END STATEMENT DO – END does not correspond to 1 : 1. Modify the program.
125 FORMAT ERROR IN MACRO <Formula> format is erroneous. Modify the program.
126 ILLEGAL LOOP NUMBER In DOn, 1x n x3 is not established. Modify the program.
127 NC, MACRO STATEMENT IN SAME
BLOCK
NC and custom macro commands coexist.
Modify the program.
128 ILLEGAL MACRO SEQUENCE
NUMBER
The sequence number specified in the branch command was not 0 to
9999. Or, it cannot be searched. Modify the program.
129 ILLEGAL ARGUMENT ADDRESS An address which is not allowed in <Argument Designation > is used.
Modify the program.
130 ILLEGAL AXIS OPERATION An axis control command was given by PMC to an axis controlled by
CNC. Or an axis control command was given by CNC to an axis
controlled by PMC. Modify the program.
131 TOO MANY EXTERNAL ALARM
MESSAGES
Five or more alarms have generated in external alarm message.
Consult the PMC ladder diagram to find the cause.
132 ALARM NUMBER NOT FOUND No alarm No. concerned exists in external alarm message clear.
Check the PMC ladder diagram.
133 ILLEGAL DATA IN EXT. ALARM
MSG
Small section data is erroneous in external alarm message or exter-
nal operator message. Check the PMC ladder diagram.
135 SPINDLE ORIENTATION PLEASE Without any spindle orientation , an attempt was made for spindle
indexing. Perform spindle orientation.
136 C/H–CODE & MOVE CMD IN SAME
BLK.
A move command of other axes was specified to the same block as
spindle indexing addresses C, H. Modify the program.

Leave a Reply