OPERATION
3.MANUAL OPERATION
B–62764EN/01
558
Feedrate, time constant and method of automatic acceleration/
deceleration for manual rapid traverse are the same as G00 in programmed
command.
Changing the mode to the jog mode while pressing a feed axis and
direction selection switch does not enable jog feed. To enable jog feed,
enter the jog mode first, then press a feed axis and direction selection
switch.
If reference position return is not performed after power–on, pushing
RAPID TRAVERSE button does not actuate the rapid traverse but the
remains at the JOG feedrate. This function can be disabled by setting
parameter RPD (No.1401#01).
Limitations
D Acceleration/decelera-
tion for rapid traverse
D Change of modes
D Rapid traverse prior to
reference position return