FANUC Series 16/18/160/180-Model C Machining Center Operators Manual

OPERATION
4. AUTOMATIC OPERATION
B–62764EN/01
606
Move the cursor and enter the file numbers and number of repetitions
in the order in which to execute the files. At this time, the current
number of repetitions “CUR.REP” is 0.
5 Press the
REMOTE switch on the machine operators panel to enter
the
RMT mode, then press the start switch. The files are executed in
the specified order. When a file is being executed, the cursor is
positioned at the number of that file.
The current number of repetitions
CUR.REP is increased when M02
or M30 is executed in the program being run.
O0000 N02000
RMT
**** *** ***
10 : 10 : 40
FILE DIRECTORY
ORDERFILE NO. REQ.REP CUR.REP
01 5 5
02 0003 23 23
03 0004 9999 156
04 0005 LOOP 0
05
06
07
08
09
10
PRGRM
(OPRT)
DIR
Screen No.5
SCHDUL
0007
If no file number is specified on screen No. 4 (the file number field is left
blank), program execution is stopped at that point. To leave the file
number field blank, press numeric key
0
then
INPUT
.
If a negative value is set as the number of repetitions,
<LOOP> is
displayed, and the file is repeated indefinitely.
When the
[(OPRT)], [CLEAR], and [EXEC] soft keys are pressed on
screen No. 4, all data is cleared. However, these keys do not function
while a file is being executed.
When the soft key
[PRGRM] is pressed on screen No. 1, 2, 3, 4, or 5, the
program screen is displayed.
Up to 9999 can be specified as the number of repetitions. If 0 is set for a
file, the file becomes invalid and is not executed.
By pressing the page key on screen No. 4, up to 20 files can be registered.
When M codes other than M02 and M30 are executed in a program, the
current number of repetitions is not increased.
Explanations
D Specifying no file
number
D Endless repetition
D Clear
D Return to the program
screen
Restrictions
D Number of repetitions
D Number of files
registered
D M code