FANUC Series 16/18/160/180-Model C Machining Center Operators Manual

OPERATION
7. ALARM AND SELF–DIAGNOSIS
FUNCTIONS
B–62764EN/01
656
Up to 25 of the most recent CNC alarms are stored and displayed on the
screen.
Display the alarm history as follows:
Procedure for Alarm History Display
1 Press the function key
MESSAGE
.
2 Press the chapter selection soft key
[HISTRY].
The alarm history appears.
The following information items are displayed.
(1)The date the alarm was issued
(2)Alarm No.
(3)Alarm message (some contains no message)
3 Change the page by the 1–page change key.
4 To delete the recorded information, press the softkey
[(OPRT)] then
the
[DELETE] key.
ALARM HISTORY O0100 N00001
MEM
**** *** ***
19 : 47 : 45
(1)95.02.14 16:43:48
(2)010 (3)MPROPER G–CODE
95.02.13 8:22:21
506 OVER TRAVEL : +1
95.02.12 20:15:43
417 SERVO ALARM : X AXIS DGTL PARAM
ALARM
MSG
HISTRY
(OPRT)
PAGE=1
(4)
(1) The date the alarm was issued
(2) Alarm No.
(3) Alarm message (some contains no message)
(4) Page No.
7.2
ALARM HISTORY
DISPLAY