OPERATION
11. SETTING AND DISPLAYING DATA
B–62764EN/01
746
To perform floating reference position return with a G30.1 command, the
floating reference position must be set beforehand.
Procedure for setting the floating reference position
1 Press function key
POS
to display a screen used for displaying the
current position.
2 Move the tool to the floating reference position by jogging.
3 Press soft key
[(OPRT)].
4 Press soft key
[SET FRP].
5 To register the floating reference positions for all axes, press soft key
[ALLEXE].
To register the floating reference position of a specific axis, enter the
name of the axis [
X
,
Y
, etc.), then press soft key [EXEC]. Two
or more names can be entered consecutively (e.g.,
X
Y
Z
[EXEC]).
The above operation stores the floating reference position. It can be
checked with parameter (no. 1244).
6 In step 4, the floating reference position along a specified axis can
also be stored by entering the axis name (such as
X
or
Y
) and
pressing soft key
[SET FRP].
By parameter FPC (bit 3 of parameter 1201), the relative position can be
preset to 0 when a floating reference position is registered.
11.1.7
Setting the Floating
Reference Position
Procedure
SET FRP
EXEC
RELABS
ALL
(OPRT)
ALLEXE
Explanations
D Presetting the relative
coordinate system