FANUC Series 16/18/160/180-Model C Machining Center Operators Manual

OPERATION
B–62764EN/01
11. SETTING AND DISPLAYING DATA
751
Displays the block currently being executed and modal data in the
MEMORY or MDI mode.
Procedure for displaying the current block display screen
1 Press function key
PROG
.
2 Press chapter selection soft key
[CURRNT].
The block currently being executed and modal data are displayed.
The screen displays up to 22 modal G codes and up to 11 G codes
specified in the current block.
(CURRNT) (MODAL)
G01 X 17.500 G67 G01 F 2000
G17 F 2000 G54 G17
G41 H 2 G64 G91
G80 G69 G22
G15 G94
G40 .1 G21 H 2 D
G25 G41
G49 T
G80
G98 S
G50
> _ S 0 T0000
MEM STRT *** 16:05:59
[ PRGRM ] [ CHECK ] [ CURRNT ] [ NEXT ] [ (OPRT) ]
PROGRAM O2000 N00130
The current block display screen is not provided for 14–inch CRTs or
9.5–inch LCDs. Press soft key
[PRGRM] to display the contents of the
program on the right half of the screen. The block currently being
executed is indicated by the cursor. Modal data is displayed on the left
half of the screen. The screen displays up to 18 modal G codes.
ACTUAL POSITION
(ABSOLUTE)
X 0.000
Y 0.000
Z 30.000
G00 G40 G54 F 500 M 3
G17 G43 G64
G90 G80 G69 H 5
G22 G90 G15 D T 9
G94 G50 G25
G21 G67 S 6000
SACT 0
O3001 N00000
F 0
ABS
REL ALL
PRGRM
NEXT (OPRT)
PROGRAM
O3001 ;
G40 ;
G49 M06 T9 ;
G0 G54 G90 X0 Y0 ;
G43 Z30. H5 S6000 M3 ;
M0 ;
X17.5 Y–22 ;
Z–6.5 ;
G10 P11 R0.995 F500 ;
M30 ;
%
>_
MEM **** *** *** 07:07:40
+
(MODAL)
MM/MIN
11.2.2
Current Block Display
Screen
Procedure
Explanations
D 14-inch CRT screen
9.5–inch LCD screen

Leave a Reply

Your email address will not be published. Required fields are marked *