FANUC Series 16/18/160/180-Model C Machining Center Operators Manual

OPERATION
B–62764EN/01
11. SETTING AND DISPLAYING DATA
779
If a block containing a specified sequence number appears in the program
being executed, operation enters single block mode after the block is
executed.
Procedure for sequence number comparison and stop
1 Select the MDI mode.
2 Press function key
OFFSET
SETTING
.
3 Press chapter selection soft key
[SETING].
4 Press page key
PAGE
or
PAGE
several times until the following screen
is displayed.
SETTING (HANDY) O0001 N00000
> _
MDI **** *** *** 16:05:59
[ OFFSET ] [ SETING ] [ WORK ] [ ] [ (OPRT) ]
PARAMETER WRITE = 1 (0:DISABLE 1:ENABLE)
TV CHECK = 0 (0:OFF 1:ON)
PUNCH CODE = 1 (0:EIA 1:ISO)
INPUT UNIT = 0 (0:MM 1:INCH)
I/O CHANNEL = 0 (0–3:CHANNEL NO.)
SEQUENCE NO. = 0 (0:OFF 1:ON)
TAPE FORMAT = 0 (0:NO CNV 1:F10/11)
SEQUENCE STOP = 0 (PROGRAM NO.)
SEQUENCE STOP = 11 (SEQUENCE NO.)
5 Enter in (PROGRAM NO.) for SEQUENCE STOP the number (1 to
9999) of the program containing the sequence number with which
operation stops.
6 Enter in (SEQUENCE NO.) for SEQUENCE STOP (with five or less
digits) the sequence number with which operation is stopped.
7 When automatic operation is executed, operation enters single block
mode at the block containing the sequence number which has been
set.
11.4.4
Sequence Number
Comparison and Stop
Procedure