FANUC Series 16/18/160/180-Model C Machining Center Operators Manual

APPENDIX
G. ALARM LIST
B–62764EN/01
892
Number ContentsMessage
5051 M–NET CODE ERROR When the chopping function is used, a move command was specified
for a chopping axis in chopping mode (during reciprocation between
a top dead point and bottom dead point).
5052 M–NET ETX ERROR “ETX” code is abnormal.
5053 M–NET CONNECT ERROR Connection time supervision error (parameter No.175)
5054 M–NET RECEIVE ERROR Boring time supervision error (parameter No.176)
5055 M–NET PRT/FRM ERROR Vertical parity or framing error detection
5057 M–NET BOARD SYSTEM DOWN Transmit time–out error (parameter No. 177)
ROM parity error
CPU interruption detection of not listed above
5060 ILLEGAL PARAMETER IN
G02.3/G03.3
Parameter setting is illegal.
No. 5641 (setting of the linear axis) is not specified.
No. 5641 specifies an axis other than a linear axis.
No. 5642 (setting of the rotation axis) is not specified.
No. 5642 specifies an axis other than a rotation axis.
The CNC cannot control the linear or rotation axis (the value of No.
1010 is exceeded).
5061 ILLEGAL FORMAT IN G02.3/G03.3 The command for exponential interpolation (G02.3/G03.3) contains a
format error.
Address I, J, or K is not specified.
Addresses I, J, and K are 0.
5062 ILLEGAL COMMAND IN
G02.3/G03.3
The command for exponential interpolation (G02.3/G03.3) contains
an illegal value.
The specified value is not suitable for exponential interpolation (for
example, a negative value is subject to ln).
5063 IS NOT PRESET AFTER REF. This message is output when the position counter has not been
preset before the start of plate thickness measurement. This alarm is
issued in one of the cases below.
1) When an attempt was made to perform measurement before a refer-
ence position had been established.
2) When, after manual reference position return, an attempt was made
to start measurement without first setting the position counter.
5064 DIFFERRENT AXIS UNIT
(IS–B, IS–C)
Circular interpolation was specified for a plane formed by axes using
different increment systems.
5065 DIFFERRENT AXIS UNIT
(PMC AXIS)
In PMC–based axis control, axes using different increment systems
are specified for the same DI/DO group. Modify parameter No. 8010.
5066 RESTART ILLEGAL SEQUENCE
NUMBER
During program restart using the return/restart function, a sequence
number between 7000 and 7999 was read while performing search
for the next sequence number.
5068 G31 P90 FORMAT ERROR No axis is specified for movement.
Two or more axes were specified for movement.
5069 WHL–C; ILLEGAL P–DATA The P data, specified for selecting the compensation center for grind-
ing wheel wear compensation, is invalid.
5073 NO DECIMAL POINT A decimal point is not specified for a command for which a decimal
point must be specified.
5074 ADDRESS DUPLICATION ERROR The same address appears more than once in a block. Alternatively,
a block contains two or more G codes belonging to the same group.
5082 DATA SERVER ERROR Details are displayed on the data server message screen.
5085 SMOOTH IPL ERROR 1 A block for specifying smooth interpolation contains a syntax error.