Fanuc Symbol CAPi T Operators Manual

B–63304EN/02
2. INPUT/OUTPUT AND
COLLATION OF DATA
VARIOUS FILE AND DATA
225
To cancel the deletion of the file, just enter (INPUT). Then, the
previous submemory file directory screen is redisplayed.
If an incorrect password is entered, the deletion is canceled, and the
previous submemory file directory screen is redisplayed.
If the correct password is entered, the file is deleted.
5. Replacing a protected file
(1)When replacement is specified, the following message apperas:
REPLACE OK? [file name searched for] (1: OK 0: NO)
REP = _
Enter 1 (INPUT). Then, the file is replaced with the data in main
memory.
(2)If the file to be replaced is protected, the following message
appears:
THIS FILE IS PROTECTED
IF YOU WANT TO REPLACE THIS FILE, KEY IN PASSWORD
PLEASE
PW = _
Enter the threedigit number set in system parameter No.739 (123
in the example 1.).
To cancel the replacement, just enter (INPUT). Then, the previous
submemory input/output screen is redisplayed.
If an incorrect password is entered, the replacement is canceled,
and the previous submemory input/output screen is redisplayed.
If the correct password is entered, the file is replaced.
NOTE
1 If the auxiliary operation, SUBMEMORY INITIALIZATION,
is executed, all files including protected files are deleted.
2 If no password is defined (system parameter No.739) or if
the password does not consist of three digits, protected files
cannot be deleted.

Leave a Reply