Fanuc Symbol CAPi T Operators Manual

B–63304EN/02
3. SETTING DATA,
SYSTEM PARAMETER, MTF
SETTING AND DISPLAY OF DATA
291
(1)Press the DATA SET soft key on the initial screen. The screen of
parameter and data setting will appear.
(2)To the question, NO. = , key in,
NO. = 2
INPUT
and the setting data list screen will appear.
For system parameter and MTF, key in,
NO. = 1
INPUT
in this screen.
(3)The screen will change, and another NO. = will be questioned, so
key in,
NO. = 1
INPUT
(System parameter)
or
NO. = 5
INPUT
(MTF)
and the screen with a list of system parameter or MTF will appear.
(Function of the soft keys)
[CURSOR ±] [CURSOR °] The cursor proceeds or retreats.. .
[SEARCH NO.] Used to select the setting number. . . .
Key in the searching number and press this soft
key without pressing INPUT, to the question, and
the cursor moves to the number of the input
number.
If INPUT is pressed then, the data will be replaced.
[END] Pressed when all setting has ended.. . . . . . . . . . .
[SAVE END] Press SAVE END to save the data in the. . . . .
submemory.
3.1
DISPLAY AND
SETTING