Fanuc Symbol CAPi T Operators Manual

VARIOUS FUNCTIONS AND
PRECAUTIONS OF Symbolic FAPT
B–63304EN/02
1. VARIOUS FUNCTIONS OF
Symbolic FAPT
346
If entered data is erroneous, one of the following error massages appears:
(1)G CODE IS ILLEGAL
Example 1: A G code that cannot be used is specified.
G00X100Y200;
Example 2: A space is placed before a G code.
G01X200;
Space
(2)ILLEGAL DATA FORMAT
Example 1: G code contains a space.
G242X 100Y200;
G242 X100Y200;
Example 2: Decimal point is set in G code.
G242X100.Y200;
Example 3: G code contains more than one sign.
G242X+–100;
Example 4: Arguments are specified in reverse order.
G242Y200X100;
Example 5: An argument is omitted.
G245;
Example 6: An argument that cannot be used is specified.
G204X100Y200P5;
Example 7: An argument value exceeds the maximum.
G204X1234;
G243P2038,
;
When the “INPUT” key is pressed, error checking is performed.
(3)DRAWING IMPOSSIBLE
Example 1: A G code other than G240 is specified between G245 and
G246.
G245;
G01X100; ² Illegal
G246;
Example 2: G246 is specified alone, without G245.
When the “CHECK” soft key is pressed, these errors are detected.
If an error occurs, the cursor blinks on the illegal line.
(4)NO DATA
If there is no drawing data, this error message appears when the
“CHECK” soft key is pressed.
(5)DATA AREA OVERFLOW
Up to 432 lines of data can be set on the initial screen display data
setting screen. If an attempt is made to insert data beyond 432 lines,
this message appears.
(6)TOO MANY GRAPHIC SPECIFICATIONS
If the work area provided for graphic display overflows, this message
appears.
(7)TOO MANY CHARACTERS
If the work area provided for character display overflows, this message
appears.
1.12.4
Error Messages