Fanuc Symbol CAPi T Operators Manual

VARIOUS FUNCTIONS AND
PRECAUTIONS OF Symbolic FAPT
B–63304EN/02
1. VARIOUS FUNCTIONS OF
Symbolic FAPT
350
(2)Function tables (MTF Nos. in the range 2000 to 2999)
******** 16TA/TTA format initial values ********
<Existing table>
2059 =5802, 6302, 1101, 0001, 0903, 0503, 0004, 0000, 0000, 0000
G98 G84 X Z R F ;
G99 G88
2203 =5802, 6002, 6102, 1101, 0001, AA01, 0903, 0C03, 0503, 0B03
G98 G98 G83 X Z C R P F K
G99 G87
2204 =0004, 0000, 0000, 0000
;
2205 =5802, 6002, 6202,
1101, 0001, AA01, 0903, 0A03, 0503, 0B03
G98 G98 G83 X Z C R Q F K
G99 G87
2206 =0004, 0000, 0000, 0000
;
2207 =5802, 6002, 6302,
1101, 0001, AA01, 0903, 1505, 0203, 0005
G98 G98 G84 X Z C R M?? S M03
G99 G88
2208 =0503, 0B03, 0004, 0000
F K ;
2209 =0102, 5702, 0107, 8107, 0004, 6402, AA01, 0004, 0000, 0000
G1 G18 W0 H0 ; G107 C ;
G19
2210 =6402, AA01, 0004, 0000
G107 C ;
* The underlined function codes have been changed for the new function. (See (2) of Section 2.2.)
<New table
2214 =6502, 0004, 0000, 0000
G112 ;
2215 =6602, 0004, 0000, 0000
G113 ;
Tapping cycle command
block (turning)
Drilling cycle
command block
Peck drilling cycle, or
high–speed peck drilling
cycle command block
Tapping cycle, or rigid
tapping cycle command
block (C–axis)
Cylindrical interpolation
start block
Cylindrical interpolation
cancel block
Polar coordinate interpolation start block
Polar coordinate interpolation cancel block