The outputted NC data becomes as follows.
NOTE
NC data of the process 1 2 is omitted.
%;
O10:
G50X400.Z400.;
M05;
M50;
G50X300.Z300.;
G00T0101;
G97S2000M13;
X40.;
Z92.;
G17G98G81Z85.R92.F350.;
M21;
M21;
M21;
G00Z300.;
X300.;
T0100;
M01;
G50X300.Z300.;
G00T0202 ;
G97S1393M13 ;
X40. ;
Z92. ;
M21 ;
G82Z75.R92.P80.F139. ;
M21 ;
M21 ;
M21 ;
G00Z300. ;
X300. ;
T0200 ;
M01 ;
G50X300.Z300. ;
G00T0303 ;
G97S1593M13 ;
X40. ;
Z92. ;
M21 ;
G84Z76.R92.F318. ;
M21 ;
M21 ;
M21 ;
C00Z300. ;
X300. ;
T0300 ;
M01 ; ½
G50X300.Z300. ;
G00T0404 ;
G97S1393M13 ;
Z25. ;
X104. ;
M22 ;
G19G82X83.R104.P0.08F139.
M23 ;
G00X300. ;
Z300. ;
T0400 ;
M01 ;
G50X300.Z300. ;
G00T0505 ;
G97S2587M13 ;
Z50. ;
X104. ;
M24 ;
X79. ;
G01X70.F26. ;
Z66.F65. ;
G00X79.;
X104.;
Z50.;
M24.;
X79.;
G01X70.F26.;
Z66.F65.;
G00X79.;
X104.;
X300.;
Z300.;
T0500;
M01;
X400.Z400.;
M01;
M05;
M30;
%