Fanuc Symbol CAPi T Operators Manual

C–AXIS FAPT FUNCTION
B–63304EN/02
8. CAXIS FAPT FUNCTION B
508
(1)In case parameter TH (Through hole) is set to “0”
(2)In case parameter TH (Through hole) is set to “1”
NOTE
1 Whether fixed cycle is used in the generated NC data or not
is determined by the MTF parameter No.1304.
2 When the parameter DW is set to “1”, Dwell is programmed
at the bottom of the hole.Dwell Time is specified by the
system parameter No.395.
3 Retracting feed rate is calculated as follows.
FT x [Override value for retracing feedrate of C–AXIS
REAMING. (System Parameter No.392)]