Fanuc Symbol CAPi T Operators Manual

B–63304EN/02
8. CAXIS FAPT FUNCTION BC–AXIS FAPT FUNCTION
521
(2)Function Table
No. Description Remarks
2216 FIXED BORING cycle 1 (NO.1) BORING
2217 FIXED BORING cycle 1 (NO.2) BORING
2218 FIXED BORING cycle 2 (NO.1) FINE BORING
2219 FIXED BORING cycle 2 (NO.2) FINE BORING
2226 Start of CAXIS REAMING
FS16/18–TC, FS16i/18iTA CAP II only
2227 Start of CAXIS BORING
2236 End of CAXIS REAMING
2237 End of CAXIS BORING
2250 Spindle orientation
Referred to for CAXIS BORING type 2
2251 Spindle restart
(Not using fixed cycle).
D Default settings for MTF2216–2251
MTF 2216= 5702, 5802, 6002,6702,1101,0001, AA01, 0903,0C03,0503
G17 G98 G98 G89 X Z C R P F
G18 G99
G19
MTF 2217= 0B03, 0004, 0000,0000,0000
L ;
K
MTF 2218= 5702, 5802, 6002,6702,1101,0001, AA01, 0903,1603,1803 (5E00 SERIES)
G17 G98 G98 G86. 1 X Z C R Q I
G18 G99
G19
MTF 2219= 1703, 0C03,0503,0B03,0004,0000, 0000, 0000 (5E00 SERIES)
K P F L ;
MTF 2226= 0100, 0000, 0000,0000,0000,0000 (5900, 5F00 SERIES)
FEED
MTF 2227= 0100, 0000, 0000,0000,0000,0000 (5900, 5F00 SERIES)
FEED
MTF 2236= 0100, 0000, 0000,0000,0000,0000 (5900, 5F00 SERIES)
FEED
MTF 2237= 0100, 0000, 0000,0000,0000,0000 (5900, 5F00 SERIES)
FEED
MTF 2250= 1805, 0004, 0000,0000,0000,0000
M19 ;
MTF 2251= 0005, 0004, 0000,0000,0000,0000
M03 ;
M04
Settings of MTF2216/2217/2218/MTF2219 for the SERIES other
than 5E00 are as follows.
MTF 2216= 5802, 6002, 6702,1101,0001,AA01, 0903, 0C03,0503,0B03
G98 G98 G85 X Z C R P F L
G99 G78 K
MTF 2217= 0004, 0000, 0000,0000
;
MTF 2218= 0000, 0000, 0000,0000,0000,0000, 0000, 0000,0000,0000
MTF 2219= 0000, 0000, 0000,0000,0000,0000, 0000, 0000