Fanuc Symbol CAPi T Operators Manual

B–63304EN/02
3. SPECIFYING HOME AND INDEX
POSITIONS (MENU 3)
Y–AXIS FAPT FUNCTION
553
3
SPECIFYING HOME AND INDEX POSITIONS (MENU 3)
On the HOME & INDEX POSITION screen of menu 3, the following
prompts are displayed. Program a diameter as the X coordinate and a
radius as the Y and Z coordinates.
Home position DXH =
ZH =
YH =
Index position DXI =
ZI =
YI =
The initial values can be specified in system parameters 0207 to 0229.
These prompts can be skipped if bit 3 of system parameter 0009 is
specified accordingly.