Fanuc Symbol CAPi T Operators Manual

PROGRAMMING AND
OPERATION BY Symbolic FAPT
B–63304EN/02
3. EXECUTION OF
Symbolic FAPT
60
The parts figure input system includes the system of entering the
definition data with displaying a defined figure, and the method of
entering the definition data while displaying in the table format. The
former is called Graphic input system (refer to para. 3.2.2 and 3.2.3 II)
and the latter is called Directory input system. The Directory input
system” will be described here.
(1)In the screen of the graphic input system, press the soft key “LIST
MODE”.
[LIST MODE] The figure element input screen of the. . . .
directory input system is selected.
In this screen, select the element to be modified, using ELEMENT
FORWARD and ELEMENT BACK soft keys. (when the element is
inserted, it is inserted before the element is selected.)
Next, press “INPUT” when changing the figure data.
When it is desired to insert the element, key in the element symbol and
press “INPUT”. When only checking the data without modifying it,
check the objective element data, using ELEMENT FORWARD and
ELEMENT BACK soft keys.
(2)When the element is changed or inserted, the figure data input screen
is selected. The inquiry is displayed under the figure data list display.
3.2.5
Part Figure Input
(Directory Input
System)