Fanuc Symbol CAPi T Operators Manual

B–63304EN/02
3. EXECUTION OF
Symbolic FAPT
PROGRAMMING AND
OPERATION BY Symbolic FAPT
61
In this screen, all data on the figure data are inquired. Adjust the cursor
to the data to be entered and input the data. Upon completion of
keying–in operation, press NEXT PAGE soft key.
(3)[NEXT PAGE] Again, the figure element input screen is. . . .
selected.
At this time, the modified data is registered on
the list screen.
[END] If END is pressed when the data input or modification is. . .
completed, the display returns to the screen that the
figure data input is completed.
However, when an error is produced in the parts figure
data, it will not return to that screen 1 but will become
figure element input screen and the Key in Again
message is displayed.
In this case, modify the figure data of this element.
[GRAPH MODE] Press GRAPHIC MODE soft key to return to. .
the graphic input screen from the directory
input screen. At this time the position of the
element shown by the cursor will become the
same position with the elements where the
cursor was blinking in the directory input
system.
Drawing is also carried out up to its position
from the beginning.
(1)Chamfering
Normally, it is customary practice to chamfer a corner unless
otherwise specified for the machined parts in the drawing. Unlike the
specified chamfer, this chamfering is not described in the drawing, the
chamfering amount is constant and many in most cases.
Consequently, when the machined figure is prepared, it may be
troublesome to enter many chamfering elements. This function inputs
a given amount of chamfer exclusively to all corners to which no
chamfer (element symbol C) is input yet after all machined figures are
completely entered.
After the machined figure for turning is entered, the following screen
is displayed.
3.2.6
Batch Input Functions
for Chamfering and
Corner R