Fanuc Symbol CAPi T Operators Manual

APPENDIX
B–63304EN/02
A. SETTING DATA,
SYSTEM PARAMETER, MTF
834
Parameter
No.
RemarksDescription
Initial
value
Format
0447 Integer 80 Cutting depth D1 (Percentage of the tool diameter)
0448 Real number Undefined Can’t use. (Dont change the data.)
0449 Real number
2. mm specification
Clearance CD in the longitudinal direction
and clearance C1 in the circumferential
0.08 inch specification
direction of the tool for Yaxis contouring
Unit: mm or inches
0450 Real number
0.5 mm specification
Finishing allowance of Yaxis contouring
0.02 inch specification
TS
Unit: mm or inches
0451 to
0459
Real number Undefined Can’t use. (Dont change the data.)
0578 Integer Undefined Color of the axes of a slanted surface coordinate system
(FANUC standard value = 4, blue)
0700 0, 1
designation (8 bits)
00000000 Can’t use. (Dont change the data.)
0701 0, 1
designation (8 bits)
00000000
Bit 2 When interference alarm sounded:
0 : Stop drawing
1 : Continue drawing
Bit 3 Animation drawing in manual operation mode
0 : Disable
1 : Enable
Bit 4 Center line is
0 : Drawn
1 : Not drawn
Bit 5 Interference check is
0 : Executed
1 : Not executed
Bit 6 By executing M30, blank is
0 : Not redrawn
1 : Redrawn
Bit 7 The setting of parameters for drawing is
0: Possible
1: Prohibited
7 6 5 4 3 2 1
0
0
0
Bit
Parameter
for
animation
drawing