Fanuc Symbol CAPi T Operators Manual

APPENDIX
B–63304EN/02
A. SETTING DATA,
SYSTEM PARAMETER, MTF
866
(c) Output of G code
When the least significant 1 digit (major classification) is 2 ...
***2;
Most significant
3 digits (detailed
classification)
Least significant
1 digit (major
classification)
Function Remarks
0 0 0 2 G code output (G00) set to
MTF 1200
Output of G code of MTF 1200 1207
0 1 0 2 G code output (G01) set to
MTF 1201
CAUTION
The G code of MTF 1200 1207, MTF 1210
1211, MTF 1220 1225, and MTF 1230 1232 is
0 2 0 2 G code output (G02) set to
MTF 1202
model managed for each group. Thus, when the
function code specifying these G code is referred
to, the G code is output only when it is different
0 3 0 2 G code output (G03) set to
MTF 1203
from the G code output. Also, this G code is not
output when 1 is set to MTF 1200 1251.
0 4 0 2 G code output (G32) set to
MTF 1204
0 5 0 2 G code output (G92) set to
MTF 1205
0 6 0 2 G code output (G90) set to
MTF 1206
0 7 0 2 G code output (G94) set to
MTF 1207
1 0 0 2 G code output (G97) set to
MTF 1210
G code output of MTF 1210 1211
1 1 0 2 G code output (G96) set to
MTF 1211
2 0 0 2 G code output (G40) set to
MTF 1230
G code output of MTF 1230 1232
2 1 0 2 G code output (G41) set to
MTF 1231
2 2 0 2 G code output (G42) set to
MTF 1232
3 0 0 2 G code output set to MTF
1220
G code output of MTF 1220 1225
3 1 0 2 G code output set to MTF
1221
3 2 0 2 G code output set to MTF
1222
3 3 0 2 G code output set to MTF
1223
3 4 0 2 G code output set to MTF
1224
3 5 0 2 G code output set to MTF
1225