Fanuc Symbol CAPi T Operators Manual

B–63304EN/02
A. SETTING DATA,
SYSTEM PARAMETER, MTF
APPENDIX
873
(g)Output of special M code (range selection, turret selection)
When the least significant 1 digit (major classification) is 6 ...
***6;
Most significant
3 digits (detailed
classification)
Least significant
1 digit (major
classification)
Function Remarks
0 0 0 6 Spindle range selection M
code
The M code (MTF 1110 1113) corresponding to the
selected range is output. Also, the M code of MTF
1110 1113 is modal managed.
0 0 0 6 Turret selection M code
output (unused)
The M code of MTF 1054 1056 is output. Currently
it is not used.
(h)Value 0 code output
When the least significant 1 digit (major classification) is 7 ...
***7;
Most significant
3 digits (detailed
classification)
Least significant
1 digit (major
classification)
Function Remarks
0 0 0 7 Z0 output The first character
address of MTF 1040
0 1 0 7 W0 output The second character
address of MTF 1040
1 0 0 7 X0 The first character
address of MTF 1041
1 1 0 7 U0 The second character
address of MTF 1041
3 0 0 7 K0 The first character
address of MTF 1042
3 1 0 7 K0 The second character
address of MTF 1042
4 0 0 7 K0 The first character
address of MTF 1043
4 1 0 7 K0 The second character
address of MTF 1043
5 0 0 7 J0 The first character
address of MTF 1049
5 1 0 7 J0 The second character
address of MTF 1049
6 0 0 7 F0 The first character
address of MTF 1044
6 1 0 7 F0 The second character
address of MTF 1044
7 0 0 7 F0 The first character
address of MTF 1045
7 1 0 7 F0 The second character
address of MTF 1045