Fanuc Symbol CAPi T Operators Manual

APPENDIX
B–63304EN/02
A. SETTING DATA,
SYSTEM PARAMETER, MTF
874
Most significant
3 digits (detailed
classification)
RemarksFunction
Least significant
1 digit (major
classification)
8 0 0 7 C0 output The first character
address of MTF 1300
8 1 0 7 H0 output The second character
address of MTF 1300
9 0 0 7 Outputting a
reference
position
return for the
tool angular
axis (B0)
Address set in
MTF1405
(i) Arbitrary M, S, T code output
When the significant 1 digit (major classification) is 8, 9, A.
Most significant
3 digits (detailed
classification)
Least significant
1 digit (major
classification)
Function Remarks
M code value 8 M code output
S code value 9 S code output
T code value A T code output
NOTE
With the function codes of major classes 8, 9 and A, the M,
S, T code specified by the first 3 digits of the function code
is output. The value of the M, S, T code to be output is
specified by a 3digit hexadecimal number.
8: M code
9: S code
0: T code
output M, S, T code value
(hexadecimal number)
Example)
The function code to output S100 is specified as follows.
0649
Indicateds that the address to be
output is S.
Expresses the value to be output
100 in a hexadecimal number.