Fanuc Symbol CAPi T Operators Manual

B–63304EN/02
A. SETTING DATA,
SYSTEM PARAMETER, MTF
APPENDIX
875
(j) Fixed word output
The least significant 1 digit (major classification) is F ... ***F
Most significant
3 digits (detailed
classification)
Least significant
1 digit (major
classification)
Function Remarks
0 0
0 F Only address characters are output
a: ASCII code of output address
to
F F
(a)
1
to
7
(b)
F Subsequent to address characters, the
following 1word value is output.
b: Output digit number
8
to
F
(b)
F Subsequent to address characters, the
following 2word value is output.
b: Total output digit number
b–8: No. of digits past the decimal point
Example 1)
If the function code is set to 503F, 0064, the following is output as NC
data output.
P100
Example 2)
Set No. MTF 2200 as follows.
2200 = 0705, 504F, 1F40, 0004, 0000, 0000, 0000, 0000, 0000, 0000
NC data at the Caxis machining head part is output as follows.
M98P8000;
CAUTION
1 Any other function code than those listed in this table is
undefined. Any other code than them must not be set to the
function table.
2 Difference between CC01 and 0107, between DD01 and
1107.
If the latter parameter is referred to, W0 and U0 are output
always. Besides, for the former parameter, W0 and U0 are
output only when it is the symmetry axis resulting from
division.