Fanuc Symbol CAPi T Operators Manual

B–63304EN/02
A. SETTING DATA,
SYSTEM PARAMETER, MTF
APPENDIX
899
Example 2
When the following is specified, another function table can be
referenced from the referenced function table.
MTF 2000= 0300, 0104, 0004, 0603, 0004, 000E, 1700, 0000, 0000, 0000
FEED % ; 0 : MTF2300
MTF 2300= 0605, 0004, 000E, 1701, 0000, 0000, 0000, 0000, 0000,0000
M01 ; MTF2301
MTF 2301= 000A, 0004, 0000, 0000, 0000, 0000, 0000, 0000, 0000, 0000
T0000 ;
(4)Notes
NOTE
Do not have a table reference itself. Also, do not reference
the referencing table again from the referenced table.
If a table is referenced in this way, the output of the same
function table continues until memory is full, then the
following message is output and processing stops.
WARNING! CHECK INPUT DATA
When this message is displayed, check and correct the
function table and output the NC data again.
Example 1)
Setting in which a table references itself
MTF 2300= 0605, 0004, 000E, 1701, 0000, 0000, 0000, 0000, 0000, 0000
M01 ; MTF2300
The table references itself.
Example 2)
Setting in which a referencing table is referenced again from the
referenced table
MTF 2300= 0605, 0004, 000E, 1701, 0000, 0000, 0000, 0000, 0000, 0000
M01 ; MTF2301
MTF 2301= 0028, 0004, 000E, 1702, 0000, 0000, 0000, 0000, 0000, 0000
M02 ; MTF2302
MTF 2302= 0038, 0004, 000E, 1700, 0000, 0000, 0000, 0000, 0000, 0000
M03 ; MTF2300
The referencing table is referenced
again from the referenced table.