PDF Fanuc Power Mate i-D/H Parameter Manual

4. DESCRIPTION OF PARAMETERS
B63180EN/02
94
3170 Number of connected Power Mate units
[Data type] Byte
[Valid data range] 0 to 16 (128 to 144)
CRTMAX When the CRT/MDI is shared by multiple Power Mate units, set the
number of connected Power Mate units. In this parameter, set equipment
parameter #0 only. When 0 is specified, the connection of two Power Mate
units is set. When at least one Power Mate unit with three or more
controlled axes is to be connected, set a value equal to 128 plus the number
of Power Mate units.
#7
DMM3191
#6 #5 #4 #3 #2 #1 #0
[Data type] Bit
DMM When a FANUCmade touch panel is used, switching to a fullscreen
display is:
0 : Not performed.
1 : Performed.
#7
3201
#6
NPE
#5
N99
#4 #3 #2
REP
#1
RAL
#0
RDL
[Data type] Bit
RDL When a program is registered by input/output device external control
0 : The new program is registered following the programs already
registered.
1 : All registered programs are deleted, then the new program is
registered.
Note that programs which are protected from being edited are not
deleted.
RAL When programs are registered through the reader/puncher interface
0 : All programs are registered.
1 : Only one program is registered.
REP Action in response to an attempt to register a program whose number is
the same as that of an existing program
0 : An alarm is generated.
1 : The existing program is deleted, then the new program is registered.
Note that if the existing program is protected from being edited, it is
not deleted, and an alarm is generated.
N99 With an M99 block, when bit 6 (NPE) of parameter No.3201 = 0, program
registration is assumed to be:
0 : Completed
1 : Not completed
NPE With an M02, M30, or M99 block, program registration is assumed to be:
0 : Completed
1 : Not completed

Leave a Reply