PDF Fanuc Power Mate i-D/H Parameter Manual

4. DESCRIPTION OF PARAMETERS
B63180EN/02
96
CPD When an NC program is deleted, a confirmation message and
confirmation soft key are:
0 : Not output.
1 : Output.
PSR Search for the program number of a protected program
0 : Disabled
1 : Enabled
#7
MCL3203
#6
MER
#5
MIE
#4 #3 #2 #1 #0
[Data type] Bit
MZE After MDI operation is started, program editing during operation is:
0 : Enabled
1 : Disabled
MER When the last block of a program has been executed at single block
operation in the MDI mode, the executed block is:
0 : Not deleted
1 : Deleted
NOTE
When MER is set to 0, the program is deleted if the
endofrecord mark (%) is read and executed. (The mark %
is automatically inserted at the end of a program.)
MCL Whether a program prepared in the MDI mode is cleared by reset
0 : Not deleted
1 : deleted
#7
3204
#6
MKP
#5
SPR
#4
P9E
#3
P8E
#2
EXK
#1 #0
PAR
[Data type] Bit
PAR Characters [ and ] on a keyboard are:
0 : Used as [ and ].
1 : Used as ( and ).
EXK The input character extension function is:
0 : Not used.
1 : Used. (Soft key [CEXT] is not displayed.)
NOTE
The [CEXT] soft key is used to select an operation on the
program screen. This soft key enables the entry of (, ),
and @ using soft keys.